Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 215
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
2.
Int J Cardiol ; : 131934, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38437953

RESUMO

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.

3.
JACC Cardiovasc Interv ; 17(1): 76-87, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38199755

RESUMO

BACKGROUND: Knowledge about atrial functional tricuspid regurgitation (afTR) in transcatheter aortic valve replacement (TAVR) patients is scarce. OBJECTIVES: The aim of the study was to analyze the association between the entity and the development of tricuspid regurgitation (TR) in patients undergoing TAVR for aortic stenosis and concomitant TR. METHODS: We analyzed patients undergoing TAVR for severe aortic stenosis from January 2013 to December 2020 and concomitant at least moderate TR at baseline. afTR was defined as enlargement of the right atrium in relation to the right ventricle. TR development after TAVR and 3-year all-cause mortality were evaluated. RESULTS: Out of 3,474 TAVR patients, we identified 420 patients with concomitant at least moderate TR. A total of 363 patients were included in the study, with 178 patients stratified in the afTR and 185 in the non-afTR group based on a receiver-operating characteristic curve cutoff of 1.132 of the right atrial/right ventricular area ratio. TR improvement after TAVR was observed in significantly less patients with afTR compared with non-afTR (31.1% vs 60.6%; P < 0.001). Multivariate regression analysis confirmed afTR as independent predictor for TR persistence (adjusted OR: 2.80; 95% CI: 1.66-4.76; P < 0.001). Moreover, afTR was associated with aggravation of TR after TAVR (17.0% vs 6.8%; P = 0.013). Three-year all-cause mortality was significantly higher in patients with persistence compared with patients with improvement of TR (P < 0.001). CONCLUSIONS: In TAVR patients, afTR is an independent predictor for TR persistence. Moreover, TR persistence is associated with increased 3-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Átrios do Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
4.
Chemphyschem ; 25(1): e202300636, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37955910

RESUMO

The availability of high-resolution 3D structural information is crucial for investigating guest-host systems across a wide range of fields. In the context of drug discovery, the information is routinely used to establish and validate structure-activity relationships, grow initial hits from screening campaigns, and to guide molecular docking. For the generation of protein-ligand complex structural information, X-ray crystallography is the experimental method of choice, however, with limited information on protein flexibility. An experimentally verified structural model of the binding interface in the native solution-state would support medicinal chemists in their molecular design decisions. Here we demonstrate that protein-bound ligand 1 H NMR chemical shifts are highly sensitive and accurate probes for the immediate chemical environment of protein-ligand interfaces. By comparing the experimental ligand 1 H chemical shift values with those computed from the X-ray structure using quantum mechanics methodology, we identify significant disagreements for parts of the ligand between the two experimental techniques. We show that quantum mechanics/molecular mechanics (QM/MM) molecular dynamics (MD) ensembles can be used to refine initial X-ray co-crystal structures resulting in a better agreement with experimental 1 H ligand chemical shift values. Overall, our findings highlight the usefulness of ligand 1 H NMR chemical shift information in combination with a QM/MM MD workflow for generating protein-ligand ensembles that accurately reproduce solution structural data.


Assuntos
Imageamento por Ressonância Magnética , Proteínas , Simulação de Acoplamento Molecular , Ligantes , Espectroscopia de Ressonância Magnética/métodos , Proteínas/química
5.
IEEE Trans Vis Comput Graph ; 30(1): 1161-1171, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37871083

RESUMO

We introduce two novel visualization designs to support practitioners in performing identification and discrimination tasks on large value ranges (i.e., several orders of magnitude) in time-series data: (1) The order of magnitude horizon graph, which extends the classic horizon graph; and (2) the order of magnitude line chart, which adapts the log-line chart. These new visualization designs visualize large value ranges by explicitly splitting the mantissa m and exponent e of a value v=m·10e. We evaluate our novel designs against the most relevant state-of-the-art visualizations in an empirical user study. It focuses on four main tasks commonly employed in the analysis of time-series and large value ranges visualization: identification, discrimination, estimation, and trend detection. For each task we analyze error, confidence, and response time. The new order of magnitude horizon graph performs better or equal to all other designs in identification, discrimination, and estimation tasks. Only for trend detection tasks, the more traditional horizon graphs reported better performance. Our results are domain-independent, only requiring time-series data with large value ranges.

6.
Catheter Cardiovasc Interv ; 103(1): 186-193, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38140761

RESUMO

BACKGROUND: Patients undergoing transcatheter aortic valve implantation (TAVI) frequently have coronary artery disease requiring percutaneous coronary intervention (PCI). Usually, PCI and TAVI are performed in two separate procedures and current studies are investigating potential benefits regarding the order. However, the two interventions may also be performed simultaneously, thereby limiting the risk associated with repeated vascular access. Data evaluating benefit and harm of concomitant procedures are scarce. AIMS: Therefore, this study aimed to evaluate concomitant PCI (coPCI) in TAVI patients regarding Valve Academic Research Consortium 3 (VARC-3) endpoints and long-term mortality. METHODS: A total of 2233 consecutive TAVI patients from the EVERY-VALVE registry were analyzed according to the VARC-3 endpoint definitions. A total of 274 patients had undergone TAVI and concomitant PCI (coPCI group). They were compared to 226 TAVI patients who had received PCI within 60 days before TAVI in a stepwise approach (swPCI group) and to the remaining 1733 TAVI patients who had not undergone PCI recently (noPCI group). RESULTS: Overall median age was 81.4 years, median Society of Thoracic Surgeons score was 4.0%. Patients in the coPCI and in the swPCI group were predominantly male with reduced left-ventricular ejection fraction. Rates of VARC-3 composite endpoints technical success and 30-day device success were comparable between all three groups. Mortality rates at 3 years after TAVI were similar (coPCI, 34.2% vs. swPCI, 31.9% vs. noPCI, 34.0% p = 0.84). CONCLUSIONS: coPCI during TAVI seems comparable in a retrospective analysis. Compared to a stepwise approach, it has similar rates of composite endpoints technical success and device success as well as long-term mortality.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Estudos Retrospectivos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
7.
Eur J Heart Fail ; 25(12): 2243-2251, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37905381

RESUMO

AIM: Functional or secondary tricuspid regurgitation (STR) is the most common phenotype of tricuspid regurgitation (TR) with atrial STR (ASTR) and ventricular STR (VSTR) being recently identified as two distinct entities. Data on tricuspid transcatheter edge-to-edge repair (T-TEER) in patients with STR according to phenotype (i.e. ASTR vs. VSTR) are lacking. The aim of this study was to assess characteristics and outcomes of patients with ASTR versus VSTR undergoing T-TEER. METHODS AND RESULTS: Patients with STR undergoing T-TEER were selected from the Transcatheter Tricuspid Valve Therapies (TriValve) registry. ASTR was defined by (i) left ventricular ejection fraction ≥50%, (ii) atrial fibrillation, and (iii) systolic pulmonary artery pressure <50 mmHg. Patients not matching these criteria were classified as VSTR. Patients with primary TR and cardiac implantable electronic device were excluded. Key endpoints included procedural success and survival at follow-up. A total of 298 patients were enrolled in the study: 65 (22%) with ASTR and 233 (78%) with VSTR. Procedural success was similar in the two groups (80% vs. 83% for ASTR vs. VSTR, p = 0.56) and TEER was effective in reducing TR in both groups (from 97% of patients with baseline TR ≥3+ to 23% in ASTR and to 15% in VSTR, all p = 0.001). At 12-month follow-up, survival was significantly higher in the ASTR versus VSTR cohort (91% vs. 72%, log-rank p = 0.02), with VSTR being an independent predictor of mortality at multivariable analysis (hazard ratio 4.75). CONCLUSIONS: In a real-world, multicentre registry, T-TEER was effective in reducing TR grade in both ASTR and VSTR. At 12-month follow-up, ASTR showed better survival than VSTR.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Volume Sistólico , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/etiologia , Função Ventricular Esquerda , Sistema de Registros
8.
Sci Rep ; 13(1): 15375, 2023 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-37717041

RESUMO

The recruitment of cross-hemispheric counterparts of lateralized prefrontal brain regions with increasing processing demand is thought to increase memory performance despite cognitive aging, but was recently reported to be present also in young adults working at their capacity limit. Here we ask if cross-hemispheric recruitment is a general strategy of the adult brain in that executive task demand would modulate bilateral activation beyond prefrontal cortex and across cognitive tasks. We analyzed data sets from two fMRI experiments investigating retrospective working memory maintenance and prospective action planning. We confirmed a cross-hemispheric recruitment of prefrontal cortex across tasks and experiments. Changes in lateralization due to planning further surfaced in the cerebellum, dorsal premotor and posterior parietal cortex. Parietal cortex thereby exhibited cross-hemispheric recruitment also during spatial but not verbal working memory maintenance. Our results confirm a domain-general role of prefrontal cortex in cross-hemispheric recruitment. They further suggest that other task-specific brain regions also recruit their idling cross-hemispheric counterparts to relocate executive processing power.


Assuntos
Encéfalo , Cerebelo , Adulto Jovem , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Encéfalo/diagnóstico por imagem , Memória de Curto Prazo
9.
JACC Cardiovasc Interv ; 16(16): 1965-1973, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648344

RESUMO

BACKGROUND: Patients with severe aortic regurgitation (AR) are often not considered for surgery because of increased surgical risk. Because of unique anatomical characteristics among patients with AR, interventional treatment options are limited, and implantation results are inconsistent compared with those among patients with aortic stenosis. OBJECTIVES: The authors describe the initial commercial experience of the first Conformité Européenne-marked transfemoral transcatheter aortic valve replacement system (JenaValve Trilogy [JV]) for the treatment of patients with AR. METHODS: This multicenter registry included 58 consecutive patients from 6 centers across Germany. Transcatheter aortic valve replacement was performed with the JV system for isolated severe and symptomatic AR. Patient characteristics, primary implantation outcomes, and valve performance up to 30 days were analyzed using Valve Academic Research Consortium 3 definitions. RESULTS: The mean patient age was 76.5 ± 9 years, with a mean Society of Thoracic Surgeons score of 4.2% ± 4.3%. Device success was achieved in 98% of patients. The mean gradient was 4.3 ± 1.6 mm Hg, and no moderate or severe paravalvular regurgitation occurred. No conversion to open heart surgery or valve embolization was reported. There were no major vascular complications or bleeding events. The rate of new permanent pacemaker implantation was 19.6%. At 30 days, 92% of the patients were in NYHA functional class I or II, and the 30-day mortality rate was 1.7%. CONCLUSIONS: Treatment of patients with severe symptomatic AR using the transfemoral JV system is safe and effective. Given its favorable hemodynamic performance and low complication rates, this system may offer a new treatment option for patients with AR not suitable for surgery.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
10.
Clin Res Cardiol ; 112(10): 1427-1435, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37337011

RESUMO

BACKGROUND: Cardiohepatic syndrome (CHS) has been identified as an important but underrecognized survival predictor in multiple cardiovascular disease entities. The objectives of this study were to evaluate the prevalence and prognostic value of CHS in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: The study included patients with available laboratory parameters of hepatic function who underwent TAVR from July 2013 until December 2019 at our center. CHS was defined as an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal (bilirubin, alkaline phosphatase, and gamma glutamyl transferase). Study endpoints were three-year survival, technical and device failure (VARC 3), as well as New York Heart Association (NYHA) functional class at follow-up. RESULTS: Among a total of 953 analyzed patients (47.6% females, median age 80.0 [76.0-85.0] years) CHS was present in 212 patients (22.4%). In patients with vs. without CHS, rates of technical (6.1% vs. 8.4%, p = 0.29) and device failure (18.9% vs. 17.3%, p = 0.59) were comparable. NYHA functional class at baseline and follow-up was more severe in patients with CHS. Nevertheless, heart failure symptoms improved from baseline to follow-up irrespective of hepatic function. Three-year survival rates were significantly lower in patients with CHS (49.4 vs. 65.4%, p < 0.001). The predictive value of CHS persisted after adjustment in a multivariable analysis (hazard ratio 1.58, p < 0.01). CONCLUSION: In patients undergoing TAVR, CHS is prevalent in 22% of patients and is associated with increased postinterventional mortality. Thus, CHS should be included in the decision-making process within the TAVR heart team. Cardiohepatic syndrome (CHS) as defined by an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal was prevalent in 22% of patients undergoing TAVR for severe AS. The presence of CHS was associated with more severe heart failure symptoms and worse three-year survival.


Assuntos
Estenose da Valva Aórtica , Colestase , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
11.
EuroIntervention ; 19(6): 526-536, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37042426

RESUMO

BACKGROUND: Concomitant moderate/severe mitral regurgitation (MR) is observed in 17-35% of patients undergoing transcatheter aortic valve implantation (TAVI) and contributes to a worse prognosis. Studies analysing outcomes in patients undergoing TAVI with different MR aetiologies, including atrial functional MR (aFMR), are lacking. AIMS: We aimed to analyse outcomes and changes in MR severity in patients with aFMR, ventricular functional (vFMR) and primary mitral regurgitation (PMR) following TAVI. METHODS: We analysed all consecutive patients with at least moderate MR undergoing TAVI between January 2013 and December 2020 at the Munich University Hospital. Characterisation of MR aetiology was performed by detailed individual echocardiographic assessment. Three-year mortality, changes in MR severity and New York Heart Association (NYHA) Functional Class at follow-up were assessed. RESULTS: Out of 3,474 patients undergoing TAVI, 631 patients showed MR ≥2+ (172 with aFMR, 296 with vFMR, 163 with PMR). Procedural characteristics and endpoints were comparable between groups. The rate of MR improvement was 80.2% in aFMR patients, which was significantly higher compared to both other groups (vFMR: 69.4%; p=0.03; PMR: 40.8%; p<0.001). The estimated 3-year survival rates did not differ between aetiologies (p=0.57). However, MR persistence at follow-up was associated with increased mortality (hazard ratio 1.49, 95% confidence interval: 1.04-2.11; p=0.027), mainly driven by the PMR subgroup of patients. NYHA Class improved significantly in all groups. In patients with baseline MR ≥3+, the PMR aetiology was associated with the lowest MR improvement, the lowest survival rates and least symptomatic improvement. CONCLUSIONS: TAVI reduces MR severity and symptoms in patients with aFMR, vFMR and less-pronounced PMR. The presence of aFMR was associated with the greatest MR severity improvement.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Resultado do Tratamento , Prognóstico , Ecocardiografia , Estenose da Valva Aórtica/diagnóstico , Índice de Gravidade de Doença , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
12.
Artigo em Inglês | MEDLINE | ID: mdl-36948892

RESUMO

BACKGROUND: Data regarding the impact of the tricuspid valve gradient (TVG) after tricuspid transcatheter edge-to-edge repair (TEER) are scarce. OBJECTIVES: This study sought to evaluate the association between the mean TVG and clinical outcomes among patients who underwent tricuspid TEER for significant tricuspid regurgitation. METHODS: Patients with significant tricuspid regurgitation who underwent tricuspid TEER within the TriValve (International Multisite Transcatheter Tricuspid Valve Therapies) registry were divided into quartiles based on the mean TVG at discharge. The primary endpoint was the composite of all-cause mortality and heart failure hospitalization. Outcomes were assessed up to the 1-year follow-up. RESULTS: A total of 308 patients were included from 24 centers. Patients were divided into quartiles of the mean TVG as follows: quartile 1 (n = 77), 0.9 ± 0.3 mm Hg; quartile 2 (n = 115), 1.8 ± 0.3 mm Hg; quartile 3 (n = 65), 2.8 ± 0.3 mm Hg; and quartile 4 (n = 51), 4.7 ± 2.0 mm Hg. The baseline TVG and the number of implanted clips were associated with a higher post-TEER TVG. There was no significant difference across TVG quartiles in the 1-year composite endpoint (quartiles 1-4: 35%, 30%, 40%, and 34%, respectively; P = 0.60) or the proportion of patients in New York Heart Association class III to IV at the last follow-up (P = 0.63). The results were similar after adjustment for clinical and echocardiographic characteristics (composite endpoint quartile 4 vs quartile 1-quartile 3 adjusted HR: 1.05; 95% CI: 0.52-2.12; P = 0.88) or exploring post-TEER TVG as a continuous variable. CONCLUSIONS: In this retrospective analysis of the TriValve registry, an increased discharge TVG was not significantly associated with adverse outcomes after tricuspid TEER. These findings apply for the explored TVG range and up to the 1-year follow-up. Further investigations on higher gradients and longer follow-up are needed to better guide the intraprocedural decision-making process.

13.
Eur J Heart Fail ; 25(6): 872-884, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36994662

RESUMO

AIMS: The impact of the cardio-hepatic syndrome (CHS) on outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) for relevant mitral regurgitation (MR) is unknown. The objectives of this study were three-fold: (i) to characterize the pattern of hepatic impairment, (ii) to investigate the prognostic value of CHS, and (iii) to evaluate the changes in hepatic function after M-TEER. METHODS AND RESULTS: Hepatic impairment was quantified by laboratory parameters of liver function. In accordance with existing literature, two types of CHS were distinguished: ischaemic type I CHS (elevation of both transaminases) and cholestatic type II CHS (elevation of two out of three parameters of hepatic cholestasis). The impact of CHS on 2-year mortality was evaluated using a Cox model. The change in hepatic function after M-TEER was assessed by laboratory testing at follow-up. We analysed 1083 patients who underwent M-TEER for relevant primary or secondary MR at four European centres between 2008 and 2019. Ischaemic type I and cholestatic type II CHS were observed in 11.1% and 23.0% of patients, respectively. Predictors for 2-year all-cause mortality differed by MR aetiology. While in primary MR cholestatic type II CHS was independently associated with 2-year mortality, ischaemic CHS type I was an independent mortality predictor in secondary MR patients. At follow-up, patients with MR reduction ≤2+ (obtained in 90.7% of patients) presented with improved parameters of hepatic function (median reduction of 0.2 mg/dl, 0.2 U/L and 21 U/L for bilirubin, alanine aminotransferase and gamma-glutamyl transferase, respectively, p < 0.01). CONCLUSIONS: The CHS is frequently observed in patients undergoing M-TEER and significantly impairs 2-year survival. Successful M-TEER may have beneficial effects on CHS.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Fígado , Resultado do Tratamento , Cateterismo Cardíaco
14.
JACC Cardiovasc Interv ; 16(4): 396-411, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858659

RESUMO

BACKGROUND: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined. OBJECTIVES: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD. METHODS: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site-related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score). RESULTS: Among the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site-related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049). CONCLUSIONS: Among patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.


Assuntos
Ataque Isquêmico Transitório , Doença Arterial Periférica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Resultado do Tratamento , Sistema de Registros
15.
Int J Cardiol ; 376: 100-107, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36758861

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a well-established, safe and effective therapy for severe symptomatic aortic stenosis (AS). The aim of this study was to objectively quantify improvement of physical activity after TAVR, with consideration of different low-gradient AS subtypes. METHODS AND RESULTS: All patients undergoing TAVR for severe AS were screened. Participants received a wearable activity tracker (Fitbit®) at hospital discharge following TAVR and 6 months thereafter. The difference of median daily steps was defined as surrogate outcome for physical activity. For analysis, patients were grouped into high-gradient (HG) AS (dPmean ≥40 mmHg), classical low-flow low-gradient (LFLG) AS (dPmean <40 mmHg, EF <50%), paradoxical LFLG-AS (dPmean <40 mmHg, EF ≥50%, SVi ≤35 ml/m2) and normal-flow low-gradient (NFLG) AS (dPmean <40 mmHg, EF ≥50%, SVi >35 ml/m2) according to mean transvalvular pressure gradient (dPmean), stroke volume index (SVi) and left-ventricular ejection fraction (LVEF). RESULTS AND CONCLUSIONS: The analysis is based on 230 patients. The median daily step count was 4409 [IQR 2581-7487] after hospital discharge and 5326 [IQR 3045-8668] 6 months thereafter. Median difference of daily steps was ∆529 [IQR -702-2152]). Patients with HG-AS and paradoxical LFLG-AS showed a significant improvement of daily steps (∆951 [IQR -378-2323], p <0.001 and (∆1392 [IQR -609-4444], p = 0.02, respectively). Patients with classical LFLG-AS showed no statistically relevant improvement of daily steps (∆192 [IQR -687-770], p = 0.79). Patients with NFLG-AS showed a numerical decline in daily steps without statistical significance (∆-300 [IQR -1334-1406], p = 0.67). This first prospective study of this sample size shows significant improvement of physical activity after TAVR with an objective and reproducible method. This was mainly driven by an improvement in patients with HG-AS and paradoxical LFLG-AS.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Exercício Físico , Resultado do Tratamento , Índice de Gravidade de Doença
16.
Artigo em Inglês | MEDLINE | ID: mdl-36847676

RESUMO

OBJECTIVES: Severe mitral regurgitation (MR) and tricuspid regurgitation (TR) aggravate haemodynamic stress leading to congestive heart failure with impaired hepatic function, also known as cardiohepatic syndrome (CHS). Current perioperative risk calculators do not sufficiently consider CHS and serum liver function parameters lack sensitivity to diagnose CHS. Indocyanine green and its elimination (measured by the LIMON® test) represent a dynamic and non-invasive test which correlates with the hepatic function. Nevertheless, its utility in the setting of transcatheter valve repair/replacement (TVR) to predict CHS and outcome remains unknown. METHODS: We analysed liver function and outcomes of patients undergoing TVR for MR or TR between August 2020 and May 2021 at the Munich University Hospital. RESULTS: Out of a total of 44 patients treated at the University Hospital of Munich, 21 (48%) were treated for severe MR, 20 (46%) for severe TR and 3 (7%) for both diseases. Procedural success defined as MR/TR ≤2+ was 94% among MR patients and 92% among TR patients. While classical serum liver function parameters did not change after TVR, there was a significant improvement in liver function as assessed by the LIMON® test (P ≤ 0.001). Patients with baseline indocyanine green plasma disappearance rate <12.95%/min showed significantly increased 1-year mortality (hazard ratio: 1.54, 95% confidence interval: 1.05-2.25, P = 0.027) and lower New York Hear Association class improvement (P = 0.05). CONCLUSIONS: Especially in the context of the recently stressed importance of a careful patient selection prior to the interdisciplinary treatment of valvular heart disease, the LIMON® test may provide further real-time information on the patients' cardiohepatic injury and prognosis.

17.
Front Cardiovasc Med ; 10: 1106114, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36776253

RESUMO

Background: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a valuable treatment option for patients in cardiogenic shock, but complications during decannulation may worsen the overall outcome. Therefore, the aim of this study was to compare the efficacy and safety of suture-based to pure plug-based vascular closure devices for VA-ECMO decannulation. Methods: In this retrospective study, the procedural outcome of 33 patients with suture-based Perclose ProGlide closure devices was compared to 38 patients with MANTA plug-based closure devices. Results: Rate of technically correct placement of closure devices was 88% in the suture-based group and 97% in the plug-based group (p = 0.27). There was a significant reduction of severe bleeding events during VA-ECMO decannulation in plug-based versus suture-based systems (3% vs. 21%, p = 0.04). Ischemic complications occurred in 6% with suture-based and 5% with plug-based device (p = 1.00). Pseudoaneurysm formation was detected in 3% in both groups (p = 1.00). No switch to vascular surgery due to bleeding after decannulation was necessary in both groups. Conclusion: Based on our retrospective analysis, we propose that plug-based vascular closure should be the preferred option for VA-ECMO decannulation. This hypothesis should be further tested in a randomized trial.

18.
JACC Cardiovasc Interv ; 16(2): 140-151, 2023 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-36697148

RESUMO

BACKGROUND: Secondary mitral regurgitation (SMR) is a progressive disease with characteristic pathophysiological changes that may influence prognosis. Although the staging of SMR patients suffering from heart failure with reduced ejection fraction (HFrEF) according to extramitral cardiac involvement has prognostic value in medically treated patients, such data are so far lacking for edge-to-edge mitral valve repair (M-TEER). OBJECTIVES: This study sought to classify M-TEER patients into disease stages based on the phenotype of extramitral cardiac involvement and to assess its impact on symptomatic and survival outcomes. METHODS: Based on echocardiographic and clinical assessment, patients were assigned to 1 of the following HFrEF-SMR groups: left ventricular involvement (Stage 1), left atrial involvement (Stage 2), right ventricular volume/pressure overload (Stage 3), or biventricular failure (Stage 4). A Cox regression model was implemented to investigate the impact of HFrEF-SMR stages on 2-year all-cause mortality. The symptomatic outcome was assessed with New York Heart Association functional class at follow-up. RESULTS: Among a total of 849 eligible patients who underwent M-TEER for relevant SMR from 2008 until 2019, 9.5% (n = 81) presented with left ventricular involvement, 46% (n = 393) with left atrial involvement, 15% (n = 129) with right ventricular pressure/volume overload, and 29% (n = 246) with biventricular failure. An increase in HFrEF-SMR stage was associated with increased 2-year all-cause mortality after M-TEER (HR: 1.39; CI: 1.23-1.58; P < 0.01). Furthermore, higher HFrEF-SMR stages were associated with significantly less symptomatic improvement at follow-up. CONCLUSIONS: The classification of M-TEER patients into HFrEF-SMR stages according to extramitral cardiac involvement provides prognostic value in terms of postinterventional survival and symptomatic improvement.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Volume Sistólico
19.
J Clin Med ; 12(1)2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36615162

RESUMO

Background: Heparin-induced thrombocytopenia (HIT) is a serious, immune-mediated adverse drug reaction to unfractionated heparin (UFH) affecting also patients undergoing venoarterial extracorporeal membrane oxygenation (VA-ECMO). Although the association between VA-ECMO support and the development of thrombocytopenia has long been known and discussed, HIT as one underlying cause is still insufficiently understood. Therefore, the purpose of this study was to further investigate the epidemiology, mortality, diagnosis, and clinical management of HIT occurring in VA-ECMO patients treated with UFH. Methods: We conducted a retrospective single-center study including adult patients (≥18 years) with VA-ECMO support in the cardiac intensive care unit (ICU) of the University Hospital of Munich (LMU) between January 2013 and May 2022, excluding patients with a known history of HIT upon admission. Differences in baseline characteristics and clinical outcome between excluded HIT (positive anti-platelet factor 4 (PF4)/heparin antibody test but negative functional assay) and confirmed HIT (positive anti-PF4/heparin antibody test and positive functional assay) VA-ECMO patients as well as diagnosis and clinical management of HIT were analysed. Results: Among the 373 patients included, anti-PF4/heparin antibodies were detected in 53/373 (14.2%) patients. Functional HIT testing confirmed HIT in 13 cases (3.5%) and excluded HIT in 40 cases (10.7%), corresponding to a prevalence of confirmed HIT of 13/373 (3.5%) [1.6, 5.3] and a positive predictive value (PPV) of 24.5% for the antibody screening test. The platelet course including platelet recovery following argatroban initiation was similar between all groups. One-month mortality in patients with excluded HIT was 14/40 (35%) and 3-month mortality 17/40 (43%), compared to 5/13 (38%) (p > 0.999), and 6/13 (46%) (p > 0.999) in patients with confirmed HIT. Neurological outcome in both groups measured by the cerebral performance category of survivors on hospital discharge was similar, as well as adverse events during VA-ECMO therapy. Conclusions: With a prevalence of 3.5%, HIT is a non-frequent complication in patients on VA-ECMO and was not associated with a higher mortality rate. HIT was ultimately excluded by functional essay in 75% of VA-ECMO patients with clinical suspicion of HIT and positive anti-PF4/heparin antibody test. Argatroban seems to be an appropriate and safe therapeutic option for confirmed HIT-positive patients on VA-ECMO support.

20.
Clin Res Cardiol ; 112(5): 645-655, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36637479

RESUMO

AIM: The aim of this study was to analyse the predictive value of CTA-determined tricuspid annular dilatation (TAD) on the persistence of tricuspid regurgitation (TR) in patients undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) and concomitant at least moderate TR. METHODS AND RESULTS: 288 consecutive patients treated with TAVR due to severe AS and concomitant at least moderate TR at baseline were included in the analysis. As cutoff for TAD, the median value of the CTA-determined, to the body surface area-normalized tricuspid annulus diameter (25.2 mm/m2) was used. TAD had no impact on procedural characteristics or outcomes, including procedural death and technical or device failure according to the Valve Academic Research Consortium 3 criteria. However, the primary outcome of the study-TR persistence after TAVR was significantly more frequent in patients with compared to patients without TAD (odds ratio 2.60, 95% confidence interval 1.33-5.16, p < 0.01). Multivariable logistic regression analysis, adjusting for clinical and echocardiographic baseline characteristics, which are known to influence aetiology or severity of TR, confirmed TAD as an independent predictor of TR persistence after TAVR (adjusted odds ratio 2.30, 95% confidence interval 1.20-4.46, p = 0.01). Moreover, 2 year all-cause mortality was significantly higher in patients with persistence or without change of TR compared to patients with TR improvement (log-rank p < 0.01). CONCLUSION: In patients undergoing TAVR for severe AS and concomitant at least moderate TR at baseline, TAD is a predictor of TR persistence, which is associated with increased 2-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia , Dilatação/efeitos adversos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...